Assessment of UVA-riboflavin corneal cross-linking using small amplitude oscillatory shear measurements

Επιστημονική δημοσίευση - Άρθρο Περιοδικού uoadl:2998567 35 Αναγνώσεις

Μονάδα:
Ερευνητικό υλικό ΕΚΠΑ
Τίτλος:
Assessment of UVA-riboflavin corneal cross-linking using small amplitude oscillatory shear measurements
Γλώσσες Τεκμηρίου:
Αγγλικά
Περίληψη:
PURPOSE. The effect of ultraviolet (UV)–riboflavin cross-linking (CXL) has been measured primarily using the strip extensometry technique. We propose a simple and reliable methodology for the assessment of CXL treatment by using an established rheologic protocol based on small amplitude oscillatory shear (SAOS) measurements. It provides information on the average cross-link density and the elastic modulus of treated cornea samples. METHODS. Three fresh postmortem porcine corneas were used to study the feasibility of the technique, one serving as control and two receiving corneal collagen cross-linking treatment. Subsequently, five pairs of fresh postmortem porcine corneas received corneal collagen crosslinking treatment with riboflavin and UVA-irradiation (370 nm; irradiance of 3 mW/cm2) for 30 minutes (Dresden protocol); the contralateral porcine corneas were used as control samples. After the treatment, the linear viscoelastic moduli of the corneal samples were measured using SAOS measurements and the average cross-linking densities extracted. RESULTS. For all cases investigated, the dynamic moduli of the cross-linked corneas were higher compared to those of the corresponding control samples. The increase of the elastic modulus of the treated samples was between 122% and 1750%. The difference was statistically significant for all tested samples (P ¼ 0.018, 2-tailed t-test). CONCLUSIONS. We report a simple and accurate methodology for quantifying the effects of cross-linking on porcine corneas treated with the Dresden protocol by means of SAOS measurements in the linear regime. The measured dynamic moduli, elastic and viscous modulus, represent the energy storage and energy dissipation, respectively. Hence, they provide a means to assess the changing physical properties of the cross-linked collagen networks after CXL treatment. © 2016 Association for Research in Vision and Ophthalmology Inc.. All rights reserved.
Έτος δημοσίευσης:
2016
Συγγραφείς:
Aslanides, I.M.
Dessi, C.
Georgoudis, P.
Charalambidis, G.
Vlassopoulos, D.
Coutsolelos, A.G.
Kymionis, G.
Mukherjee, A.
Kitsopoulos, T.N.
Περιοδικό:
Investigative Ophthalmology and Visual Science
Εκδότης:
Association for Research in Vision and Ophthalmology Inc.
Τόμος:
57
Αριθμός / τεύχος:
4
Σελίδες:
2240-2245
Λέξεις-κλειδιά:
collagen; riboflavin, animal; cornea; elasticity; metabolism; physiology; pig; radiation response; shear strength; ultraviolet radiation; viscosity, Animals; Collagen; Cornea; Elasticity; Riboflavin; Shear Strength; Swine; Ultraviolet Rays; Viscosity