Level of patient and operator dose in the largest cardiac centre in Greece

Επιστημονική δημοσίευση - Άρθρο Περιοδικού uoadl:2986517 48 Αναγνώσεις

Μονάδα:
Ερευνητικό υλικό ΕΚΠΑ
Τίτλος:
Level of patient and operator dose in the largest cardiac centre in Greece
Γλώσσες Τεκμηρίου:
Αγγλικά
Περίληψη:
The objective of this study was to investigate the patient and staff doses in the most frequent interventional cardiology (IC) procedures performed in Onassio, the largest Cardiac Centre in Greece. Data were collected from three digital X-ray systems for 212 coronary angiographies, 203 percutaneous transluminal coronary angioplasties (PTCA) and 134 various electrophysiological studies. Patient skin dose was measured using suitably calibrated slow radiotherapy films and cardiologist dose using suitably calibrated thermoluminescent dosemeters placed on left arm, hand and foot. Patient median dose area product (DAP) (all examinations) ranged between 6.7 and 83.5 Gy cm2. Patient median skin dose in PTCA was 799 mGy (320-1660 mGy) and in RF ablation 160 mGy (35-1920 mGy). Median arm, hand and foot dose to the cardiologist were 12.6, 27 and 13 μSv, respectively, per procedure. The great range of radiation doses received by both patients and operators confirms the need for continuous monitoring of all IC techniques. © The Author 2008. Published by Oxford University Press. All rights reserved.
Έτος δημοσίευσης:
2008
Συγγραφείς:
Tsapaki, V.
Patsilinakos, S.
Voudris, V.
Magginas, A.
Pavlidis, S.
Maounis, T.
Theodorakis, G.
Koutelou, M.
Vrantza, T.
Nearchou, M.
Nikolaki, N.
Kollaros, N.
Kyrozi, E.
Kottou, S.
Karaiskos, P.
Neofotistou, E.
Cokkinos, D.
Περιοδικό:
Radiation Protection Dosimetry
Τόμος:
129
Αριθμός / τεύχος:
1-3
Σελίδες:
71-73
Λέξεις-κλειδιά:
angiocardiography; arm; article; calibration; cardiologist; coronary artery disease; coronary care unit; digital radiography; foot; Greece; hand; heart electrophysiology; human; interventional cardiovascular procedure; major clinical study; radiation exposure; radiation measurement; radiation monitoring; radiofrequency ablation; thermoluminescence dosimetry; transluminal coronary angioplasty; angiocardiography; cardiology; catheter ablation; fluoroscopy; heart function test; interventional radiology; methodology; quality control; radiation dose; radiation monitoring; skin; standard; statistics; thermoluminescence dosimetry; transluminal coronary angioplasty, Angioplasty, Transluminal, Percutaneous Coronary; Cardiology; Catheter Ablation; Coronary Angiography; Electrophysiologic Techniques, Cardiac; Fluoroscopy; Greece; Humans; Quality Control; Radiation Dosage; Radiation Monitoring; Radiography, Interventional; Skin; Thermoluminescent Dosimetry
Επίσημο URL (Εκδότης):
DOI:
10.1093/rpd/ncn006
Το ψηφιακό υλικό του τεκμηρίου δεν είναι διαθέσιμο.