Suitability study of current endovascular aortic repair devices based on real-life anatomic data

Επιστημονική δημοσίευση - Άρθρο Περιοδικού uoadl:3035428 11 Αναγνώσεις

Μονάδα:
Ερευνητικό υλικό ΕΚΠΑ
Τίτλος:
Suitability study of current endovascular aortic repair devices based on real-life anatomic data
Γλώσσες Τεκμηρίου:
Αγγλικά
Περίληψη:
Background: There are a number of stent-grafts in the market, designed to handle difficult anatomies during endovascular aortic repair. The aim of this study is to determine which stent-graft is the most appropriate to accommodate the majority of infra-renal aortic aneurysms cases. An additional aim is to determine what stent-graft characteristics influence the suitability of the stent-graft. Research design and methods: Retrospective cohort study on the suitability of available stent-grafts for infrarenal aneurysm (AAA) repair based on real-life anatomic data. The anatomical characteristics of 235 AAA were measured manually using specialized software. All measurements were compared to the official instructions-for-use (IFU) using a purpose-specific server-side script. The proper function of the script was additionally confirmed. Results: The highest suitability rate was achieved by Medtronic Endurant. The majority of stent-grafts failed to meet the respective AAA anatomy by one IFU characteristic. Stent-grafts that failed by only one IFU characteristic by ≥80% of unsuitable cases tend to have higher suitability rates. Neck dimensions and CIA diameter are the two characteristics significantly influencing the suitability rate. Conclusions: Any stent-graft with high suitability rates should be available off-the-shelf in any vascular department in order to cover the majority of cases. For challenging cases, special advantages of the stent-grafts should be taken under consideration. © 2018, © 2018 Informa UK Limited, trading as Taylor & Francis Group.
Έτος δημοσίευσης:
2019
Συγγραφείς:
Patelis, N.D.
Malli, A.
Mylonas, K.S.
Schizas, D.
Papa, N.
Economopoulos, K.P.
Damaskos, C.
Moulakakis, K.
Katsargyris, A.
Georgopoulos, S.
Klonaris, C.
Liakakos, T.
Περιοδικό:
Expert Review of Medical Devices
Εκδότης:
Taylor and Francis Ltd.
Τόμος:
16
Αριθμός / τεύχος:
2
Σελίδες:
165-171
Λέξεις-κλειδιά:
Blood vessels; Computerized tomography; Grafting (chemical); Repair, abdominal aneurysm; Endovascular; EVAR; indications for use; suitability, Stents, abdominal aortic aneurysm; adult; aged; anatomical concepts; anthropometric parameters; artery diameter; Article; cohort analysis; common iliac artery diameter; comparative study; controlled study; endovascular aneurysm repair; female; human; major clinical study; male; neck length; renal artery aneurysm; retrospective study; blood vessel transplantation; devices; endovascular surgery; middle aged; pathology; prosthesis design; stent; treatment outcome; very elderly, Aged; Aged, 80 and over; Aortic Aneurysm, Abdominal; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Female; Humans; Male; Middle Aged; Prosthesis Design; Retrospective Studies; Stents; Treatment Outcome
Επίσημο URL (Εκδότης):
DOI:
10.1080/17434440.2019.1561268
Το ψηφιακό υλικό του τεκμηρίου δεν είναι διαθέσιμο.