Τίτλος:
Issues in relation to the repeatability of and correlation between EMG and Borg scale assessments of neck muscle fatigue
Γλώσσες Τεκμηρίου:
Αγγλικά
Περίληψη:
Introduction: The repeatability of subjective and objective assessments of neck muscle fatigue is very important with regard to the clinical applicability of these methods. Method: To establish between-days reliability, 33 healthy volunteers performed a 60% maximum voluntary isometric contraction test from a standing position in all neck movements. Cervical muscle fatigue was assessed on three separate occasions from the spectral (median frequency, MF) and amplitude (root mean square, RMS) analysis of the electromyogram (EMG) signal recorded from the cervical paraspinal group, splenius capitis, levator scapulae and sternocleidomastoid. Subjective assessment of fatigue was rated by employing the Borg scale. Intraclass correlation coefficient ICC (1,1), standard error of measurement (SEM), smallest detectable difference (SDD) indices and Pearson's correlation co-efficient were calculated for the analysis of the results. Results: Normalised median frequency (MF) slope had low repeatability and large between-day error (ICC (1,1) = 0.28-0.61; SEM = 0.33-0.60%/s; SDD = 132.7-703.2%) for the protagonist muscles of each movement. Initial median frequency (IMF) had moderate to good reliability and small error (ICC (1,1) = 0.64-0.81; SEM = 2.8-8.8 Hz; SDD = 19.9-38.5%). The RMS slope yielded also poor repeatability. The Borg assessment was more reliable than the EMG estimate though variability between sessions was still quite high (SDD = 29.2-136.5%). No correlation was found between the EMG and Borg assessment of neck muscle fatigue (r = -0.01-0.39). Conclusion: The protocol used for assessing neck muscle fatigue proved to be reliable only for the IMF but the clinical usefulness of this measure remains questionable. The lack of correlation between objective and subjective estimation of neck muscle fatigue was possibly a consequence of the poor measurement repeatability. Further research is needed to identify the factors responsible for these results on neck area. © 2005 Elsevier Ltd. All rights reserved.
Έτος δημοσίευσης:
2005
Συγγραφείς:
Strimpakos, N.
Georgios, G.
Eleni, K.
Vasilios, K.
Jacqueline, O.
Περιοδικό:
Journal of Electromyography and Kinesiology
Τόμος:
15
Αριθμός / τεύχος:
5
Σελίδες:
452-465
Λέξεις-κλειδιά:
adult; amplitude modulation; analytic method; article; Borg scale; clinical examination; controlled study; correlation analysis; correlation coefficient; electromyogram; electromyography; female; frequency analysis; human; human experiment; intermethod comparison; male; mathematical model; muscle fatigue; muscle isometric contraction; neck muscle; normal human; priority journal; rating scale; reliability; reproducibility; standing; volunteer, Adult; Algorithms; Data Interpretation, Statistical; Diagnosis, Computer-Assisted; Electromyography; Exercise Test; Exertion; Female; Humans; Isometric Contraction; Male; Middle Aged; Muscle Fatigue; Neck Muscles; Physical Endurance; Reproducibility of Results; Sensitivity and Specificity; Statistics