Posterior stabilization of cervical spine injuries using the Roy-Camille plates: A long-term follow-up

Επιστημονική δημοσίευση - Άρθρο Περιοδικού uoadl:3127193 6 Αναγνώσεις

Μονάδα:
Ερευνητικό υλικό ΕΚΠΑ
Τίτλος:
Posterior stabilization of cervical spine injuries using the Roy-Camille plates: A long-term follow-up
Γλώσσες Τεκμηρίου:
Αγγλικά
Περίληψη:
Aim: Posterior cervical spine fixation has undergone tremendous advancement in recent years. The purpose of this study is to present our experience with the Roy-Camille instrumentation for posterior cervical stabilization after injury in a long-term follow-up. Patients and methods: From 1985 to 1995, 76 patients with a lower cervical spine traumatic lesion were treated in a single institution by posterior plate stabilization using the Roy-Camille plates (R-C plates). Fifty-four men and 22 women with a mean age of 43.2 years were involved. In 59 patients the injuries were due to a road traffic accident, in 14 cases the fall from a high was responsible, while in two cases the injuries were due to sport activities. There were four bilateral dislocations, nine unilateral dislocations, 56 fracture dislocations, five fracture separations of a lateral mass and two burst fractures. Neurological lesions were present in 65 patients (9 ASIA A, 16 ASIA B, 22 ASIA C, 18 ASIA D and 11 ASIA E). All patients had minimum follow-up of 7 years. Fifty-nine patients were followed up for a mean period of 21 years (14-27 years). Results: Stability was obtained in all but two cases. Reoperation was done in two cases: in one for the correction of the lost reduction and in a second for the reinsertion of a screw irritating a nerve root. No case in the ASIA A group showed neurological improvement, a fact observed in the other groups. Conclusions: The R-C plates were used in the last quarter of the last century. This technique showed good short-time results, and we have shown good results in a long-term follow-up as well. The literature referred to this technique was favorable, as far as the biomechanical behavior and also clinical application concern. The question about this plating system abundance still remains unanswered. © 2013 Springer-Verlag France.
Έτος δημοσίευσης:
2014
Συγγραφείς:
Korres, D.
Nikolaou, V.S.
Kaseta, M.
Evangelopoulos, D.
Markatos, K.
Lazarettos, J.
Efstathopoulos, N.
Περιοδικό:
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY
Εκδότης:
Springer-Verlag France
Τόμος:
24
Αριθμός / τεύχος:
SUPPL.1
Σελίδες:
S125-S130
Λέξεις-κλειδιά:
adult; article; bone plate; bone plating system; bone screw; cervical spine; cervical spine injury; controlled study; dislocation; falling; female; follow up; human; long term care; major clinical study; male; neurologic disease; plate fixation; priority journal; reoperation; spine stabilization; sport injury; traffic accident; devices; Dislocations; injuries; percutaneous vertebroplasty; Spinal Fractures; spine fusion; treatment outcome, Adult; Bone Plates; Cervical Vertebrae; Dislocations; Female; Follow-Up Studies; Humans; Male; Reoperation; Spinal Fractures; Spinal Fusion; Treatment Outcome; Vertebroplasty
Επίσημο URL (Εκδότης):
DOI:
10.1007/s00590-013-1376-x
Το ψηφιακό υλικό του τεκμηρίου δεν είναι διαθέσιμο.