Predictors of high flow oxygen therapy failure in COVID-19-related severe hypoxemic respiratory failure

Επιστημονική δημοσίευση - Άρθρο Περιοδικού uoadl:3219559 41 Αναγνώσεις

Μονάδα:
Ερευνητικό υλικό ΕΚΠΑ
Τίτλος:
Predictors of high flow oxygen therapy failure in COVID-19-related severe hypoxemic respiratory failure
Γλώσσες Τεκμηρίου:
Αγγλικά
Περίληψη:
Background: During COVID-19 pandemic, people who developed pneumonia and needed supplemental oxygen, where treated with low-flow oxygen therapy systems and non-invasive methods, including oxygen therapy using high flow nasal cannula (HFNC) and the application of bi-level or continuous positive airway pressure (BiPAP or CPAP). We aimed to investigate the outcomes of critical COVID-19 patients treated with HFNC and unveil predictors of HFNC failure. Methods: We retrospectively enrolled patients admitted to COVID-19 wards and treated with HFNC for COVID-19-related severe hypoxemic respiratory failure. The primary outcome of this study was treatment failure, such as the composite of intubation or death during hospital stay. The association between treatment failure and clinical features was evaluated using logistic regression models. Results: One hundred thirty-two patients with a median (IQR) PaO2/FiO2 ratio 96 (63-173) mmHg at HFNC initiation were studied. Overall, 45.4% of the patients were intubated. Hospital mortality was 31.8%. Treatment failure (intubation or death) occurred in 50.75% and after adjustment for age, gender, Charlson Comorbidity index (CCI) score and National Early Warning Score 2 (NEWS2) score on admission and PaO2/FiO2 ratio and acute respiratory distress syndrome (ARDS) severity at the time of HFNO initiation, it was significantly associated with the presence of dyspnea [adjusted OR 2.48 (95% CI: 1.01-6.12)], and higher Urea serum levels [adjusted OR 1.25 (95% CI: 1.03-1.51) mg/dL]. Conclusions: HFNC treatment was successful in almost half of the patients with severe COVID-19-related acute hypoxemic respiratory failure (AHRF). The presence of dyspnea and high serum Urea levels on admission are closely related to HFNC failure. © 2022 AME Publishing Company. All rights reserved.
Έτος δημοσίευσης:
2022
Συγγραφείς:
Polydora, E.
Alexandrou, M.
Tsipilis, S.
Athanasiou, N.
Katsoulis, M.
Rodopoulou, A.
Pappas, A.
Kalomenidis, I.
Περιοδικό:
Journal of thoracic disease
Εκδότης:
AME Publishing Company
Τόμος:
14
Αριθμός / τεύχος:
4 April
Σελίδες:
851-856
Επίσημο URL (Εκδότης):
DOI:
10.21037/jtd-21-1373
Το ψηφιακό υλικό του τεκμηρίου δεν είναι διαθέσιμο.